This option allows you to install new firmware.
Connecting to Serial Port: COM5 Baud Rate 57600
PCB Version: STM / IB
Sensor Type: AQ2_5m
Serial Number: 300239
Current Interface Firmware Version: IB_10.0 New firmware installation available!
Current Driver Firmware Version: STM_10.0 New firmware installation available!
Current Status: Idle
Main Menu - What would you like to do?
1 Measurement Settings
2 Install new Firmware
3 Command Line Prompt
4 Download CSV Data from Sensor
5 Backup CSV Data to ANB Cloud
Enter your choice:
Would you like to download and install the latest firmware from anbsensors.com? [y/n]
Automatic installation
Automatically installing firmware from anbsensors.com is the quickest and easiest way to upgrade your sensor. This method requires an internet connection and will install both the Interface and Driver firmware on your sensor automatically.
To download the latest firmware from our website select 'y'.The following will be displayed:
Downloading firmware for Driver STM & Interface IB Please Wait
* Once installation begins, please ensure continous power.
Installing Interface firmware. Please Wait.
IB_20.0.hex is Interface Firmware
Now installing Firmware File 11051 Lines
99.99% Completed
Firmware installation completed in 694.77 seconds
Now installing Driver Firmware. Please Wait.
STM_20.0.hex is Driver Firmware for STM
Now installing Firmware File 5825 Lines
99.99% Completed
Firmware installation completed in 315.79 seconds
All Firmware Successfully Updated! Please power cycle to complete.
Press ENTER to exit
Ensure your sensor remains fully powered and you keep the utils window open throughout the installation process. Additionally, make sure your computer stays active and does not enter sleep or power-saving mode during this time.
For certain older sensor versions, the utils application may prompt you to repower the sensor between firmware installations
Manual installation
To install firmware manually, first download the required files. You can then use the Utils software to upload them to your sensor.
To manually install select 'n' and manually download the required Driver and Interface firmware files into the same folder as anb_utils.NB. The PCB Version displayed on the splash screen tells you which Driver (STM or ATX) and Interface (IA or IB) firmwares you need. For sensors currently running older firmware check here for which firmware version is required
Select a firmware file to install:
1 STM_20.0.hex
2 IB_20.0.hex
* Once installation begins, please ensure continuous power.
Enter file [1-2]:
STM_20.0.hex is Driver Firmware
* Turn off your sensor for 5 seconds before powering back on
Now installing Firmware File 3406 lines
99.99 % Completed
Once complete the following will be displayed:
Firmware installation completed in 327.20 seconds
Please power down your sensor, wait for 10 seconds and power back on
Would you like to install more firmware? [y/n]
Once you have power cycled your sensor you can verify the firmware has installed successfully by restarting anb_utils and checking the splash screen.
Driver and Interface firmwares should be installed together. When you have installed one, the sensor details will not be available on the splash screen. Enter to continue and install the second. When both are successfully installed the sensor details will be available after power cycling.
If you experience any issues installing the firmware, please refer to the instructions here for an alternative install method.