Skip to main content

Command Line Prompt

This option provides access to additional BMS commands. Additionally, you can view the live data stream while the sensor is in operation.

********************************************************************
ANB SENSORS
Sensor Type : BMS
Sub System Type : BMS_900
BMS Firmware Version : BMS_3.17 Latest firmware installed!
BMS Serial Number : 180001
System Date (MM/DD/YY) : 04/25/25
System Time (24 Hour) : 12:20:00
Device Connected : ANB Sensor
SD Card : Enabled
Battery Voltage Status : 8.0
Battery Voltage Maximum : 22.0
Battery Discharge Threshold : 8.0
********************************************************************

Main Menu - What would you like to do?

1 Modify Settings
2 Install New Firmware
3 Command Line Prompt
Select option 3. Command Line Prompt from the main menu in anb_utils and the following commands will be displayed:

BMS COMMANDS
******************
VERSION Display the BMS firmware revisions, serial number and time
TIME Change the date and/or time
RESUME Resume BMS operation
REBOOT Restart the BMS

Type chosen command OR ctrl-c to exit to main menu.
******************

VERSION

Type version to display the splash screen. This will take ~10s.

********************************************************************
Sensor Type : BMS
Sub System Type : BMS_900
BMS Firmware Version : BMS_3.17 Latest firmware installed!
BMS Serial Number : 180001
System Date (MM/DD/YY) : 04/25/25
System Time (24 Hour) : 12:20:00
SD Card : Enabled
Battery Voltage Status : 8.0V
Battery Voltage Maximum : 22.0V
Battery Discharge Threshold : 8.0V
********************************************************************

This pauses the BMS operation. To restart operation type resume

TIME

Type time to change the internal clock and/or calendar.

You can accept the current date/time or input new values:

To enter new date: MM/DD/YYYY
To enter new time: HH:MM

If a new date is entered, a new results file will be created.

This pauses the BMS operation. To restart operation type resume

RESUME

Type resume to restart the BMS operation. To be used after a VERSION or TIME command.

REBOOT

Type reboot to power cycle the BMS and trigger the Sensor Detection Sequence.


For further support please contact support@anbsensors.com